Brand (A)KVVG

Control cables. Brand (A)KVVG, (A)KVVG-E, (A)KVBBShv, (A)KVBShv, (A)KVKShv, (A)KPvVG, (A)KPvBbShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp

Control cables with polyvinyl chloride plastic sheathing are designed for fixed connection to electrical devices, apparatus, and terminal assemblies of electrical distribution devices with a rated alternating voltage of up to 0.66 kV, a frequency of up to 100 Hz, or a DC voltage of up to 1 kV.

Standard
GOST 1508-78

Main design elements
1. One round conductive core:
- Material:
Aluminum (AI)
- Number of conductive cores: 4; 5; 7; 10; 14; 19; 27; 37; 52; 61; -2.5 mm2
- Number of conductors: 4; 5; 7; 10; 14; - (4-10) mm2
Copper (Cu)
- Number of conductors: 4; 5; 7; 10; 14; 19; 27; 37; 52; 61; -2.5 mm2
-number of conductors 4; 5; 7; 10; 14; - (4-10) mm2

2. Insulation:
-polyvinyl chloride plastic (B)
-cross-linked polyethylene (Pv).

3. Internal filling (band insulation):
-for (A)KVVG cables made of PVC plastic;
-for cables with armor or shielding (A)KVVGЭ, (A)KVBBShv, (A)KVBShv, (A)KVKShv, (A)KPvVGЭ, (A)KPvBBShv, (A)KPvBShv, (A)KPvKShv, (A)KVBShp, (A)KVKShp, (A)KPvBShp, (A)KPvKShp - made of PVC plastic or covered with winding or longitudinal strips of polyvinyl chloride plastic.

. Screen:
-for KVVGE, KPvVGE cables made of two copper tapes or aluminum foil with overlap, copper wire must be laid along the aluminum foil.

4. Armor:
- for (A)KVBBShv, (A)KVBShv, (A)KPvBBShv, (A)KPvBShv, (A)KVBShp, (A)KPvBShp cables - armor made of 2 galvanized steel tapes;
-for cables (A)KVKShv, (A)KPvKShv, (A)KVKShp, (A)KPvKShp - made of galvanized steel wires.

5. Sheath:
-made of polyvinyl chloride plastic (B)
-made of cross-linked polyethylene (Pv).

Cable brand KVVG, AKVVG, KPvVG, AKPVVG
Control cable with insulation made of polyvinyl chloride plastic (B) or cross-linked polyethylene (PV) and a polyvinyl chloride plastic sheath, without a protective cover

Cable type KVVGE, AKVVGE, KPvVGE, AKPvVGE
With a common screen made of aluminum or copper foil, with a polyvinyl chloride plastic sheath

Main area of application
The cables are designed for installation in rooms, ducts, tunnels, in aggressive environments, where there is no mechanical impact on the cable. Installation in the ground (trenches) is permitted, provided that the cables are protected at the points where they come to the surface. Fire hazard class according to GOST 31565-2012 classification 01.B.2.5.4

Cable brand KVVGz, AKVVGz
With polyvinyl chloride plastic sheath with filling

Main area of application
The cables are designed for electrical installations requiring sealing at the point of entry into electrical equipment. Fire hazard class according to GOST 31565-2012 01.B.2.5.4

Cable brand KVBbShv, KVBShv, AKVBbShv, AKVBShv, KPvBbShv, KPvBShv, AKPvBbShv, AKPvBShv, KVKShv, AKVKShv, KVKShp, AKVKShp, KPvKShv, AKPvKShv, KPvKShp, AKPvKShp, KPvKaShv, AKPvKaShv, KPvKaShp, AKPvKaShp, KVKaShv, AKVKaShv, KVKaShp, AKVKaShp
With protective covering made of two steel tapes, with protective hose made of polyvinyl chloride plastic

Main area of application
Cables are designed for laying in rooms, channels, tunnels, in aggressive environments
Made on
Tilda